Ads Security FA700KP-ADS Guide d'installation Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
6
90 EVENT LOG ENABLES
[3]
NOTE
:
System messages are
logged when any non-zero
selection is made.
0 = None; 1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close.
Example:
To select “Alarm/Alarm Restore”, and
“Open/Close”, enter 9 (1 + 8); To select all, enter #15.
91 OPTION SELECTION
[8,0]
Options SIA-Comp Controls
Call Wait Disable
Options: 0 = None
2 = Sounder Delay (delays sounding by 15 seconds)
UL: if used, entry delay (*35) must be 30 sec. max.
4 = AAV UL: must use ADEMCO UVCM module
8 = Exit Delay Restart/Reset UL: must be disabled
#+12 = AAV and Exit Delay Restart/Reset
SIA Guidelines: Exit Delay should be enabled.
SIA-Compliant Controls: Options: Same as listed above.
Call Waiting Disable: 0 = call waiting not used
1 = call waiting disable digits (*70) entered in field *40;
(when selected, the system dials the entry in field *40
only on alternate dial attempts; this allows proper
dialing in the event call waiting service is later
canceled by the user).
92 PHONE LINE MONITOR ENABLE
UL: see Inst. Instructions for requirements
[0,0]
1 2
NOTE: Output Device must
either be programmed to be
STOPPED in field 80 or
STOPPED by Code + # + 8 +
output number.
Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min
(#+10 = 10 min; #+11 = 11 min; #+12 = 12 min;
#+13 = 13 min; #+14 = 14 min; #+15 = 15 min)
Entry 2:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble sound
2 = Same as “1”, plus programmed output device
STARTS. If either partition is armed, external
sounder activates also.
93 No. OF REPORTS IN ARMED PERIOD
PER ZONE (Swinger Suppression)
[1,0]
Restrict SIA-Comp Controls
Report Pairs Unlimited
Reports Enable
Restrict Report Pairs:
0 = Unlimited Reports; 1 = 1 report; 2 = 2 reports
SIA Guidelines: Must be set for option 1 or 2.
SIA-Compliant Controls:
Restrict Report Pairs: 1 = 1 report pair; 2 = 2 report pairs
Unlimited Reports Enable:
0 = restrict reports to the setting in entry 1
1 = unlimited reports for zones listed in zone list 7; (use
zone list 7 to enter those zones that require unlimited
reporting; these zones ignore the setting in entry 1)
DOWNLOAD INFORMATION (
94,
95)
94 DOWNLOAD PHONE No. | | | | | | | | | | | | | | | | | | |
Enter up to 20 digits, 0–9; #+11 for '
'; #+12 for '#'; #+13 for a 2-second pause. Do not fill unused
spaces. If fewer than 20 digits, exit field by pressing
. To clear entries from field, press
94
.
UL: downloading may be performed only if a technician is at the site.
95 RING COUNT FOR DOWNLOADING
[15]
NOTE: Do not enter “0” if using
FA4285/FA4286 Phone
Module.
0 = Disable Station Initiated Download;
1–14 = number of rings (1–9, # +10 =10, # +11 =11,
# +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15).
96,
97 INITIALIZE/RESET DEFAULTS
These are commands, not data fields. See page 2.
98, *99 EXIT COMMANDS
These are commands, not data fields. See page 2.
PAGER OPTIONS (160- 172)
160 PAGER 1 PHONE No. | | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
161 PAGER 1 CHARACTERS
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
162 PAGER 1 REPORT OPTIONS
Part. 1 Part. 2 common
[0,0,0]
For each partition, select from the following options:
0 = no reports sent
1 = Open/closes all users
4 = All alarms and troubles
5 = All alarms / troubles, and open/closes for all users
12 = Alarms / troubles for zones entered in zone list 9
13 = Alarms / troubles for zones entered in zone list 9,
and open/closes for all users
163 PAGER 2 PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 0–9; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
Vue de la page 5