2–1
SECTION 2
Mounting and Wiring
••••••••••••••••••••••••••••••••
In This Section
♦
Mounting the FA700KP-ADS
♦
Wiring the FA700KP-ADS
••••••••••••••••••••••••••••••••
Mounting the FA700KP-ADS
The FA700KP-ADS should be mounted using the following criteria:
• The FA700KP-ADS must be mounted indoors, and
• should be mounted at eye level for easy viewing by the user.
To mount the FA700KP-ADS, see Figure 1 and complete the following
steps:
1. Detach the case back by pushing up into the two tabs located at
the bottom of the FA700KP-ADS with the blade of a screwdriver
while pulling the case back and case front apart.
2. Locate the case back over the mounting surface such that the
opening in the case back is aligned with the wire/cable access
opening (in the mounting surface) while passing the wires/cable
through the opening in the case back.
3. Secure the case back to the mounting surface using four screws
(supplied).
Prior to attaching the case front to the case back, be sure to wire the
FA700KP-ADS as described in the "
Wiring the FA700KP-ADS
"
paragraph in this section.