4–1
SECTION 4
Initial Setup
••••••••••••••••••••••••••••••••
In This Section
Programming the Conrol
Panel
FA700KP-ADS Initialization
How to Change the ECP
Address
How to Access the Central
Station Screen
FA700KP-ADS Setup
Setting Chime Mode On/Off
••••••••••••••••••••••••••••••••
Programming the Control Panel
The FA700KP-ADS will not be fully operational unless its address in
the control panel has been enabled for an alpha console, AUI type
device, and assigned to a partition (where applicable).
Two FA700KP-ADSs may be used (addresses 1 and 2). These
addresses (in field *189) are enabled by default. If the defaults have
been changed, enable these addresses (in field *189) using an alpha-
keypad and the Data Field Programming procedures located in the
panel Installation and Setup Guide.